TGuide S96 Estrattur Awtomatizzat tal-Aċidu Nuklejku

Għoli ħafna madwar, b'192 kampjun jiġu estratti f'ġirja waħda.

L-Estrattur Awtomatizzat tal-Aċidu Nuklejku TGuide S96 jadotta l-aħħar metodu ta 'adsorbiment tal-virga manjetika u jittrasferixxi metodu ta' żibeġ manjetiku. Pjanċi tal-fond ta '96 fond u tipi differenti ta' reaġenti ta 'estrazzjoni ta' żibeġ manjetiku huma applikati biex awtomatikament jiġbdu u jippurifikaw l-aċidu nuklejku minn 1-192 demm / ċelloli / tessuti / viruses u kampjuni oħra.

Dan l-estrattur jista 'jkun mgħammar b'24 modulu ta' fluss li għandu adattabilità tajba għal kampjuni ta 'volum kbir. Huwa mgħammar b'reaġenti ppakkjati minn qabel TIANGEN u jista 'simultanjament jiġbed 1-24 kampjun. Il-volum massimu tal-kampjun immaniġġjat mill-istrument huwa 5 ml. Huwa adattat b'mod speċjali għall-estrazzjoni ta 'aċidu nuklejku ħieles fis-serum u fil-plażma. Għandu rendiment ta 'estrazzjoni għoli u purità tajba, u jista' jintuża f'oqsma bħas-sejbien tat-tumur, NIPT, eċċ.

Kat. Le Daqs tal-Ippakkjar
OSE-S96-01 1 Issettja
OSE-S96-02 1 Sett
OSE-S96-03 1 Sett

Dettall tal-Prodott

Tags tal-Prodott

Parametri Operattivi

Operating Parameters

Prinċipju

Principle

Garanziji Multipli ta 'Rendiment u Purità Ultra Għolja

Mod ta 'assorbiment taċ-ċirkolazzjoni, effiċjenza ta' rkupru ta 'żibeġ manjetiku ≥ 98%
Permezz tal-modalità ta 'adsorbiment taċ-ċirkolazzjoni b'veloċità aġġustabbli, żibeġ manjetiċi huma assorbiti fuq il-ponta tal-virga manjetika matul il-proċess ta' dixxendenza bil-mod tal-virga manjetika, sabiex bil-kundizzjoni li l-volum ta 'elużjoni jkun żgħir, l-eluwent xorta jista' jkopri l-manjetiku kollu. żibeġ u jiċċirkola għal ħafna drabi, u anke ż-żibeġ manjetiċi b'daqsijiet żgħar ta 'partiċelli jistgħu jiġu assorbiti b'mod effettiv.

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Modalità ta 'Moviment Integrat b'erba' Dimensjonijiet Tiżgura L-Aqwa Effett ta 'Taħlit

■ Il-mod ta 'moviment integrat erba' dimensjonijiet tal-moviment X / Y / Z tal-modulu integrali tad-driegħ mekkaniku u l-vibrazzjoni tal-partijiet tat-taħlit jiżguraw tħaddim stabbli u preċiżjoni għolja tal-istrument;
■ L-istrument għandu frekwenza ta 'oxxillazzjoni għolja u multi-ger aġġustabbli, li huwa adattat għal skemi differenti ta' integrazzjoni tar-reaġenti;
■ L-amplitudni tal-vibrazzjoni tista 'tiġi aġġustata b'mod adattat skont il-volum tas-soluzzjoni stabbilit mill-utent, u b'hekk jinkiseb l-aħjar effett ta' taħlit sperimentali.
Kontroll Professjonali tat-Tniġġis u Garanzija tas-Sikurezza
■ Modulu ta 'sterilizzazzjoni UV: Jista' jiżgura li l-operazzjoni fil-magna tilħaq ambjent sterili;
■ Fann kontra l-ajrusol: Żomm l-arja fl-istrument fiċ-ċirkolazzjoni biex tevita t-tniġġis mill-ajrusol;
■ Diska kontra t-taqtir: Evita b'mod effettiv kontaminazzjoni inkroċjata bejn bjar u pjanċi;
■ Operazzjoni magħluqa: Jekk il-bieb jinfetaħ aċċidentalment, l-istrument jieqaf awtomatikament biex jiżgura s-sigurtà;
■ Konsumabbli tar-reaġenti li jintremew wara l-użu: Biex tipproteġi s-sigurtà tal-persunal tal-laboratorju u l-ambjent tal-laboratorju bl-akbar mod.
Disinn Raġonevoli ta 'L-Espansibbli Matul
L-arranġament matriċi ta 'ringiela doppja u erba' pożizzjonijiet tal-pjanċi mhux biss jiżgura l-espansibilità tal-esperiment, iżda wkoll inaqqas iż-żona okkupata tal-istrument u juża b'mod effettiv l-ispazju. Taħt kundizzjonijiet limitati, jista 'jiġi estiż biex jiġbed 192 kampjun kull darba, u jiżgura kapaċità ta' estrazzjoni ta 'fluss ultra-għoli. B'moduli ta 'tisħin doppju ta' lisi / elużjoni, l-effiċjenza tal-estrazzjoni tista 'titjieb.

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Interface tal-Interazzjoni tal-Bniedem-Kompjuter intuwittiv u Faċli għall-Utent
Il-kompjuter touch ta '10.1 pulzieri huwa mgħammar b'sistema tal-Windows u operazzjoni touch, li hija sempliċi u faċli biex tużah, li tikkonforma mad-drawwiet ta' użu tal-utent. L-issettjar tal-programm jieħu kont sħiħ tal-espansibilità sperimentali, konfigurazzjoni b'ħafna parametri ħielsa, u spazju kbir ta 'integrazzjoni u żvilupp.

Gwida tal-Prodott għal TGuide S96

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Karatteristiċi

■ Għoli ħafna: 192 kampjun jistgħu jiġu estratti f'ġirja waħda.
■ Mod ta 'tħaddim: interface touch ta' 10.1 pulzieri (sistema Windows)
■ Assorbiment manjetiku tax-xoffa: Assorbiment taċ-ċiklu, effiċjenza ta 'rkupru ≥ 98%
■ Mod ta 'moviment: Moviment integrat b'erba' dimensjonijiet, li jikkonferma l-aħjar effett ta 'taħlit
■ Moduli li jistgħu jinbidlu: Jistgħu jiġu pprovduti moduli ta '24 fluss, b'volum ta' proċessar flessibbli
■ Prevenzjoni professjonali ta 'kontaminazzjoni: Evitar effettiv ta' kontaminazzjoni inkroċjata bejn bjar u pjanċi

Il-prodotti kollha jistgħu jiġu personalizzati għal ODM / OEM. Għad-dettalji,jekk jogħġbok ikklikkja Servizz Personalizzat (ODM / OEM)


  • Preċedenti:
  • Li jmiss:

  • product_certificate04 product_certificate01 product_certificate03 product_certificate02
    ×
  • Ikteb il-messaġġ tiegħek hawn u ibagħtilna

    Kategoriji ta 'prodotti